{"product_id":"mas-auwn-101-autoclave-wing-nut-aluminium-electric","title":"Electric Aluminium Wing Nut Type Autoclave | Medsor Impex","description":"\u003ch2 data-section-id=\"1ilhfn1\" data-start=\"102\" data-end=\"159\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"105\" data-end=\"159\"\u003eAutoclave Wing Nut Aluminium Electric\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3 data-section-id=\"2l0mzs\" data-start=\"161\" data-end=\"183\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"165\" data-end=\"183\"\u003eSpecifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"184\" data-end=\"532\"\u003e\n\u003cli data-section-id=\"1nm8ckb\" data-start=\"184\" data-end=\"218\"\u003e\n\u003cstrong data-start=\"186\" data-end=\"195\"\u003eType:\u003c\/strong\u003e Horizontal, Electric\u003c\/li\u003e\n\u003cli data-section-id=\"1yru24w\" data-start=\"219\" data-end=\"256\"\u003e\n\u003cstrong data-start=\"221\" data-end=\"238\"\u003eChamber Size:\u003c\/strong\u003e 310 mm × 550 mm\u003c\/li\u003e\n\u003cli data-section-id=\"o1qn6x\" data-start=\"257\" data-end=\"298\"\u003e\n\u003cstrong data-start=\"259\" data-end=\"281\"\u003eChamber Thickness:\u003c\/strong\u003e 4 mm (approx.)\u003c\/li\u003e\n\u003cli data-section-id=\"1ub8yk8\" data-start=\"299\" data-end=\"334\"\u003e\n\u003cstrong data-start=\"301\" data-end=\"316\"\u003eOuter Size:\u003c\/strong\u003e 430 mm × 600 mm\u003c\/li\u003e\n\u003cli data-section-id=\"q9l890\" data-start=\"335\" data-end=\"392\"\u003e\n\u003cstrong data-start=\"337\" data-end=\"356\"\u003eCompressed Air:\u003c\/strong\u003e Not required (electric operation)\u003c\/li\u003e\n\u003cli data-section-id=\"34nji4\" data-start=\"393\" data-end=\"425\"\u003e\n\u003cstrong data-start=\"395\" data-end=\"409\"\u003eDoor Type:\u003c\/strong\u003e Wing Nut Type\u003c\/li\u003e\n\u003cli data-section-id=\"5tp3hw\" data-start=\"426\" data-end=\"461\"\u003e\n\u003cstrong data-start=\"428\" data-end=\"448\"\u003eDesign Pressure:\u003c\/strong\u003e 2.2 kg\/cm²\u003c\/li\u003e\n\u003cli data-section-id=\"m0lvdz\" data-start=\"462\" data-end=\"498\"\u003e\n\u003cstrong data-start=\"464\" data-end=\"485\"\u003eWorking Pressure:\u003c\/strong\u003e 1.1 kg\/cm²\u003c\/li\u003e\n\u003cli data-section-id=\"1t9t221\" data-start=\"499\" data-end=\"532\"\u003e\n\u003cstrong data-start=\"501\" data-end=\"524\"\u003eDesign Temperature:\u003c\/strong\u003e 134°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"534\" data-end=\"537\"\u003e\n\u003ch3 data-section-id=\"gavue2\" data-start=\"539\" data-end=\"570\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"543\" data-end=\"570\"\u003eConstruction \u0026amp; Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"571\" data-end=\"967\"\u003e\n\u003cli data-section-id=\"18gas0c\" data-start=\"571\" data-end=\"621\"\u003e\n\u003cstrong data-start=\"573\" data-end=\"593\"\u003eHeat Uniformity:\u003c\/strong\u003e Uniform Heat Distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1vd3e83\" data-start=\"622\" data-end=\"663\"\u003e\n\u003cstrong data-start=\"624\" data-end=\"639\"\u003eInsulation:\u003c\/strong\u003e Glass Wool Insulation\u003c\/li\u003e\n\u003cli data-section-id=\"1hwf3hm\" data-start=\"664\" data-end=\"697\"\u003e\n\u003cstrong data-start=\"666\" data-end=\"681\"\u003eNet Weight:\u003c\/strong\u003e Approx. 32 kg\u003c\/li\u003e\n\u003cli data-section-id=\"4zdh0x\" data-start=\"698\" data-end=\"763\"\u003e\n\u003cstrong data-start=\"700\" data-end=\"725\"\u003eRecording Parameters:\u003c\/strong\u003e Analog Pressure \u0026amp; Temperature Gauge\u003c\/li\u003e\n\u003cli data-section-id=\"r71rby\" data-start=\"764\" data-end=\"812\"\u003e\n\u003cstrong data-start=\"766\" data-end=\"784\"\u003eSpraying Mode:\u003c\/strong\u003e Integrated Heater Element\u003c\/li\u003e\n\u003cli data-section-id=\"1m14nlf\" data-start=\"813\" data-end=\"848\"\u003e\n\u003cstrong data-start=\"815\" data-end=\"833\"\u003eOuter Trolley:\u003c\/strong\u003e Not Included\u003c\/li\u003e\n\u003cli data-section-id=\"16z5rkk\" data-start=\"849\" data-end=\"884\"\u003e\n\u003cstrong data-start=\"851\" data-end=\"869\"\u003eInner Trolley:\u003c\/strong\u003e Not Included\u003c\/li\u003e\n\u003cli data-section-id=\"1uwf2zc\" data-start=\"885\" data-end=\"926\"\u003e\n\u003cstrong data-start=\"887\" data-end=\"907\"\u003eSpraying Piping:\u003c\/strong\u003e Aluminium Piping\u003c\/li\u003e\n\u003cli data-section-id=\"15xmiwn\" data-start=\"927\" data-end=\"967\"\u003e\n\u003cstrong data-start=\"929\" data-end=\"939\"\u003eSteam:\u003c\/strong\u003e Electric Steam Generation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"969\" data-end=\"972\"\u003e\n\u003ch3 data-section-id=\"1s50e9l\" data-start=\"974\" data-end=\"999\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"978\" data-end=\"999\"\u003eOperating Details\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1000\" data-end=\"1296\"\u003e\n\u003cli data-section-id=\"12b5cl5\" data-start=\"1000\" data-end=\"1038\"\u003e\n\u003cstrong data-start=\"1002\" data-end=\"1030\"\u003eSterilizing Temperature:\u003c\/strong\u003e 121°C\u003c\/li\u003e\n\u003cli data-section-id=\"cvjfa6\" data-start=\"1039\" data-end=\"1073\"\u003e\n\u003cstrong data-start=\"1041\" data-end=\"1065\"\u003eWorking Temperature:\u003c\/strong\u003e 121°C\u003c\/li\u003e\n\u003cli data-section-id=\"ir6vmd\" data-start=\"1074\" data-end=\"1115\"\u003e\n\u003cstrong data-start=\"1076\" data-end=\"1099\"\u003eSterilization Time:\u003c\/strong\u003e 15–30 Minutes\u003c\/li\u003e\n\u003cli data-section-id=\"1jl4bn6\" data-start=\"1116\" data-end=\"1159\"\u003e\n\u003cstrong data-start=\"1118\" data-end=\"1140\"\u003eTemperature Scope:\u003c\/strong\u003e Ambient to 134°C\u003c\/li\u003e\n\u003cli data-section-id=\"elx05f\" data-start=\"1160\" data-end=\"1210\"\u003e\n\u003cstrong data-start=\"1162\" data-end=\"1180\"\u003ePiping System:\u003c\/strong\u003e Integrated Aluminium Piping\u003c\/li\u003e\n\u003cli data-section-id=\"c6xg96\" data-start=\"1211\" data-end=\"1264\"\u003e\n\u003cstrong data-start=\"1213\" data-end=\"1224\"\u003eValves:\u003c\/strong\u003e Safety Valve and Pressure Gauge Valve\u003c\/li\u003e\n\u003cli data-section-id=\"16atf9i\" data-start=\"1265\" data-end=\"1296\"\u003e\n\u003cstrong data-start=\"1267\" data-end=\"1289\"\u003ePower Consumption:\u003c\/strong\u003e 2 kW\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1298\" data-end=\"1301\"\u003e\n\u003ch3 data-section-id=\"1wdlh9g\" data-start=\"1303\" data-end=\"1325\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1307\" data-end=\"1325\"\u003eBuild \u0026amp; Design\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1326\" data-end=\"1653\"\u003e\n\u003cli data-section-id=\"1tt7khz\" data-start=\"1326\" data-end=\"1370\"\u003e\n\u003cstrong data-start=\"1328\" data-end=\"1347\"\u003eControl System:\u003c\/strong\u003e Manual Knob \/ Analog\u003c\/li\u003e\n\u003cli data-section-id=\"1nrond0\" data-start=\"1371\" data-end=\"1427\"\u003e\n\u003cstrong data-start=\"1373\" data-end=\"1391\"\u003eChamber Shape:\u003c\/strong\u003e Cylindrical, Horizontally Mounted\u003c\/li\u003e\n\u003cli data-section-id=\"7uyv69\" data-start=\"1428\" data-end=\"1467\"\u003e\n\u003cstrong data-start=\"1430\" data-end=\"1443\"\u003eLid Type:\u003c\/strong\u003e Heavy SS Wing Nut Lid\u003c\/li\u003e\n\u003cli data-section-id=\"1dcp84e\" data-start=\"1468\" data-end=\"1508\"\u003e\n\u003cstrong data-start=\"1470\" data-end=\"1490\"\u003eGasket Material:\u003c\/strong\u003e Silicone Rubber\u003c\/li\u003e\n\u003cli data-section-id=\"1v42710\" data-start=\"1509\" data-end=\"1553\"\u003e\n\u003cstrong data-start=\"1511\" data-end=\"1527\"\u003eHeater Type:\u003c\/strong\u003e Copper Immersion Heater\u003c\/li\u003e\n\u003cli data-section-id=\"ezbsyq\" data-start=\"1554\" data-end=\"1588\"\u003e\n\u003cstrong data-start=\"1556\" data-end=\"1567\"\u003eFinish:\u003c\/strong\u003e Polished Aluminium\u003c\/li\u003e\n\u003cli data-section-id=\"1n2ciqy\" data-start=\"1589\" data-end=\"1621\"\u003e\n\u003cstrong data-start=\"1591\" data-end=\"1604\"\u003eMaterial:\u003c\/strong\u003e Aluminium Body\u003c\/li\u003e\n\u003cli data-section-id=\"1trvmkv\" data-start=\"1622\" data-end=\"1653\"\u003e\n\u003cstrong data-start=\"1624\" data-end=\"1636\"\u003eVoltage:\u003c\/strong\u003e 220V AC, 50 Hz\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1655\" data-end=\"1658\"\u003e\n\u003ch3 data-section-id=\"1lhszvz\" data-start=\"1660\" data-end=\"1680\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1664\" data-end=\"1680\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1681\" data-end=\"1803\"\u003e\n\u003cli data-section-id=\"uoh6yv\" data-start=\"1681\" data-end=\"1707\"\u003eSurgical sterilization\u003c\/li\u003e\n\u003cli data-section-id=\"1jxqz8w\" data-start=\"1708\" data-end=\"1736\"\u003eLaboratory sterilization\u003c\/li\u003e\n\u003cli data-section-id=\"1hcwspe\" data-start=\"1737\" data-end=\"1774\"\u003eHospital instrument sterilization\u003c\/li\u003e\n\u003cli data-section-id=\"114532s\" data-start=\"1775\" data-end=\"1803\"\u003eIndustrial sterilization\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1805\" data-end=\"1808\"\u003e\n\u003ch3 data-section-id=\"1kilm9p\" data-start=\"1810\" data-end=\"1833\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1814\" data-end=\"1833\"\u003eSafety Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1834\" data-end=\"1941\"\u003e\n\u003cli data-section-id=\"19pje1d\" data-start=\"1834\" data-end=\"1870\"\u003eAutomatic Pressure Release Valve\u003c\/li\u003e\n\u003cli data-section-id=\"1m3n6q2\" data-start=\"1871\" data-end=\"1897\"\u003ePressure Safety Valves\u003c\/li\u003e\n\u003cli data-section-id=\"jgyfv7\" data-start=\"1898\" data-end=\"1941\"\u003eDurable and heat-resistant construction\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1943\" data-end=\"1946\"\u003e\n\u003ch3 data-section-id=\"1gh5l1n\" data-start=\"1948\" data-end=\"1975\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1952\" data-end=\"1975\"\u003eProduct Description\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1976\" data-end=\"2260\"\u003eAutoclave Wing Nut Aluminium Electric is a high-performance sterilization unit designed for hospitals, laboratories, and industrial applications. Built with a durable aluminium body and precision-engineered components, it ensures efficient and reliable sterilization.\u003c\/p\u003e\n\u003cp data-start=\"2262\" data-end=\"2505\"\u003eFeaturing a wing nut locking system, this autoclave provides secure sealing for safe operation. It delivers uniform heat distribution and operates at standard sterilization temperatures of 121°C, ensuring effective elimination of contaminants.\u003c\/p\u003e\n\u003cp data-start=\"2507\" data-end=\"2763\"\u003eWith an analog pressure and temperature monitoring system, users can easily track performance and maintain optimal sterilization conditions. Compact, robust, and easy to operate, this autoclave is a dependable solution for professional sterilization needs.\u003c\/p\u003e\n\u003chr data-start=\"2765\" data-end=\"2768\"\u003e\n\u003ch3 data-section-id=\"pm8yra\" data-start=\"2770\" data-end=\"2790\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"2774\" data-end=\"2790\"\u003eKey Features\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"2791\" data-end=\"3014\"\u003e\n\u003cli data-section-id=\"1wachye\" data-start=\"2791\" data-end=\"2827\"\u003eElectric steam generation system\u003c\/li\u003e\n\u003cli data-section-id=\"h3gdhb\" data-start=\"2828\" data-end=\"2862\"\u003eDurable aluminium construction\u003c\/li\u003e\n\u003cli data-section-id=\"4x88zr\" data-start=\"2863\" data-end=\"2904\"\u003eWing nut locking mechanism for safety\u003c\/li\u003e\n\u003cli data-section-id=\"o6a91q\" data-start=\"2905\" data-end=\"2934\"\u003eUniform heat distribution\u003c\/li\u003e\n\u003cli data-section-id=\"1p4r19o\" data-start=\"2935\" data-end=\"2981\"\u003eAnalog pressure and temperature monitoring\u003c\/li\u003e\n\u003cli data-section-id=\"10z3tdb\" data-start=\"2982\" data-end=\"3014\"\u003eCompact and efficient design\u003cbr\u003e\u003cbr\u003e\n\u003ch3 data-section-id=\"1x2htly\" data-start=\"161\" data-end=\"199\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"165\" data-end=\"199\"\u003eAdvantages \u0026amp; Application Areas\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"200\" data-end=\"500\"\u003eThe MAS AUWN 101 Autoclave is designed to deliver reliable and efficient sterilization for medical, laboratory, and industrial environments. With precise temperature and pressure control, it ensures effective sterilization of surgical instruments, laboratory equipment, glassware, and reusable tools.\u003c\/p\u003e\n\u003cp data-start=\"502\" data-end=\"793\"\u003eIts compact design and durable aluminium construction make it suitable for continuous use, offering consistent performance in hospitals, research institutions, and industrial facilities. The autoclave supports a wide range of applications, ensuring hygiene and safety across various sectors.\u003c\/p\u003e\n\u003chr data-start=\"795\" data-end=\"798\"\u003e\n\u003ch3 data-section-id=\"lh3fvt\" data-start=\"800\" data-end=\"822\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"804\" data-end=\"822\"\u003eKey Advantages\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"823\" data-end=\"1057\"\u003e\n\u003cli data-section-id=\"xl1id7\" data-start=\"823\" data-end=\"868\"\u003eAccurate temperature and pressure control\u003c\/li\u003e\n\u003cli data-section-id=\"ywc3hf\" data-start=\"869\" data-end=\"926\"\u003eUniform heat distribution for effective sterilization\u003c\/li\u003e\n\u003cli data-section-id=\"ht3f7p\" data-start=\"927\" data-end=\"983\"\u003eSuitable for medical, laboratory, and industrial use\u003c\/li\u003e\n\u003cli data-section-id=\"h3gdhb\" data-start=\"984\" data-end=\"1018\"\u003eDurable aluminium construction\u003c\/li\u003e\n\u003cli data-section-id=\"uugnv\" data-start=\"1019\" data-end=\"1057\"\u003eCompact and easy-to-operate design\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1059\" data-end=\"1062\"\u003e\n\u003ch3 data-section-id=\"1lhszvz\" data-start=\"1064\" data-end=\"1084\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1068\" data-end=\"1084\"\u003eApplications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul data-start=\"1085\" data-end=\"1253\"\u003e\n\u003cli data-section-id=\"e7xvv6\" data-start=\"1085\" data-end=\"1122\"\u003eSurgical instrument sterilization\u003c\/li\u003e\n\u003cli data-section-id=\"1upmbbu\" data-start=\"1123\" data-end=\"1161\"\u003eLaboratory equipment sterilization\u003c\/li\u003e\n\u003cli data-section-id=\"x2vztr\" data-start=\"1162\" data-end=\"1178\"\u003eHospital use\u003c\/li\u003e\n\u003cli data-section-id=\"1eer3xl\" data-start=\"1179\" data-end=\"1217\"\u003eIndustrial sterilization processes\u003c\/li\u003e\n\u003cli data-section-id=\"1d2zrn3\" data-start=\"1218\" data-end=\"1253\"\u003eResearch and testing facilities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr data-start=\"1255\" data-end=\"1258\"\u003e\n\u003ch3 data-section-id=\"1al3mln\" data-start=\"1260\" data-end=\"1315\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1264\" data-end=\"1315\"\u003eSample Policy, Domestic Market \u0026amp; Certifications\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1316\" data-end=\"1501\"\u003eSample units are available for evaluation, allowing customers to assess performance before bulk purchase. Orders are securely packaged and delivered efficiently across domestic markets.\u003c\/p\u003e\n\u003cp data-start=\"1503\" data-end=\"1686\"\u003eThe product is manufactured and supplied in India and complies with relevant quality and safety standards. It includes documentation and manuals for proper installation and operation.\u003c\/p\u003e\n\u003chr data-start=\"1688\" data-end=\"1691\"\u003e\n\u003ch3 data-section-id=\"134q5fn\" data-start=\"1693\" data-end=\"1705\"\u003e\u003cspan role=\"text\"\u003e\u003cstrong data-start=\"1697\" data-end=\"1705\"\u003eFAQs\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp data-start=\"1707\" data-end=\"1933\"\u003e\u003cstrong data-start=\"1707\" data-end=\"1777\"\u003eQ: How does the Autoclave function for sterilization?\u003c\/strong\u003e\u003cbr data-start=\"1777\" data-end=\"1780\"\u003eA: It uses steam generation and controlled pressure to sterilize instruments at temperatures up to 121°C, ensuring effective elimination of contaminants.\u003c\/p\u003e\n\u003cp data-start=\"1935\" data-end=\"2116\"\u003e\u003cstrong data-start=\"1935\" data-end=\"1991\"\u003eQ: What are the main applications of this autoclave?\u003c\/strong\u003e\u003cbr data-start=\"1991\" data-end=\"1994\"\u003eA: It is suitable for sterilizing surgical instruments, laboratory equipment, glassware, and other reusable medical tools.\u003c\/p\u003e\n\u003cp data-start=\"2118\" data-end=\"2253\"\u003e\u003cstrong data-start=\"2118\" data-end=\"2175\"\u003eQ: Where can I buy the Autoclave online?\u003c\/strong\u003e\u003cbr data-start=\"2175\" data-end=\"2178\"\u003eA: It is available through authorized manufacturers and suppliers in India.\u003c\/p\u003e\n\u003cp data-start=\"2255\" data-end=\"2421\"\u003e\u003cstrong data-start=\"2255\" data-end=\"2314\"\u003eQ: What safety features are included in this autoclave?\u003c\/strong\u003e\u003cbr data-start=\"2314\" data-end=\"2317\"\u003eA: It includes automatic pressure release valves, safety valves, and pressure gauges for safe operation.\u003c\/p\u003e\n\u003cp data-start=\"2423\" data-end=\"2567\"\u003e\u003cstrong data-start=\"2423\" data-end=\"2474\"\u003eQ: Does the autoclave support sample purchases?\u003c\/strong\u003e\u003cbr data-start=\"2474\" data-end=\"2477\"\u003eA: Yes, sample units are available, and bulk orders are supported with efficient delivery.\u003c\/p\u003e\n\u003cp data-start=\"2569\" data-end=\"2763\"\u003e\u003cstrong data-start=\"2569\" data-end=\"2630\"\u003eQ: How is the autoclave ready for use after installation?\u003c\/strong\u003e\u003cbr data-start=\"2630\" data-end=\"2633\"\u003eA: Once properly installed and connected to a power supply, it can be operated immediately following the user manual instructions.\u003c\/p\u003e\n\u003cp\u003eMedsor Impex provides premium-quality Autoclave Wing Nut Aluminium Electric Sterilizers designed for reliable steam sterilization in hospitals, clinics, laboratories, diagnostic centers, nursing homes and healthcare institutions. Engineered for professional sterilization applications, this autoclave effectively sterilizes surgical instruments, laboratory glassware, dressings, culture media and medical equipment.\u003c\/p\u003e\n\u003cp\u003eManufactured from high-quality aluminium, the autoclave offers excellent heat conductivity, lightweight construction and dependable performance. The electric heating system ensures efficient steam generation and consistent sterilization conditions, making it suitable for routine healthcare and laboratory sterilization requirements.\u003c\/p\u003e\n\u003cp\u003eThe durable wing nut locking mechanism provides secure lid closure and safe operation during sterilization cycles. Its user-friendly design allows easy operation, cleaning and maintenance, while the robust construction ensures long-lasting performance in demanding environments.\u003c\/p\u003e\n\u003cp\u003eIdeal for hospitals, research laboratories, educational institutions, diagnostic centers and healthcare facilities, the Aluminium Electric Wing Nut Autoclave delivers efficient sterilization performance, operational safety and reliability.\u003c\/p\u003e\n\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Medsor Impex","offers":[{"title":"Default Title","offer_id":50681573736695,"sku":null,"price":0.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0931\/1394\/2263\/files\/ADDC405MyFloor-1_TDICity_Kundli_Sonepat_Haryana-2026-04-14T134145.866.png?v=1776154534","url":"https:\/\/medsorimpex.com\/products\/mas-auwn-101-autoclave-wing-nut-aluminium-electric","provider":"Medsor Impex","version":"1.0","type":"link"}